ADPL-2 CH+ND
Quad Wavelength Diode and Q-Switched Nd:YAG System
Hair removal and tattoo removal from one portable cabinet. The quad wavelength diode handles the hair list, and the Q-switched Nd:YAG handles tattoos, pigment, carbon peels and fungal nail, which are the treatments that keep a clinic busy between hair appointments.
- 800W quad wavelength diode
- 500W Q-switched Nd:YAG
- Three spot sizes on the diode
- Class IIa medical device
- Six treatments
£11,499 plus VAT
Finance available, subject to status and lender approval. Engineer installation, PAT testing and accredited training included at the full price.

- TÜV Rheinland 0197
- Class IIa medical device
- MHRA registered
- Notified body certificate held
- Full test report set
- Established 2011
Registration with, or membership of, any body named here does not imply their endorsement or approval of Skintastic or of this device.
Two lasers, one cabinet, 33kg
A diode laser earns its keep on hair. A Q-switched Nd:YAG earns its keep on everything a diode cannot touch, and tattoo removal in particular is a high value list that most hair removal clinics turn away. Putting both in one portable cabinet means one purchase, one training course and one service contract.
Portable
33kg net. It moves between rooms and between sites, which matters if you rent a chair or work more than one location.
Two revenue lists
Hair reduction and tattoo removal are different clients booking at different times. One asset serves both.
One learning curve
One screen, one client record database, one alarm system, one set of local rules for your Laser Protection Adviser to write.

Six treatments from one platform
These are the treatments the machine is built and supplied to deliver. Confirm with your own insurer that the list you intend to offer is covered before you commit.
Laser hair removal
Quad wavelength diode, for permanent hair reduction across the Fitzpatrick range with the appropriate clinical protocol.
Tattoo removal
Q-switched Nd:YAG at 1064nm and 532nm, including the R20 protocol for faster clearance where the skin tolerates it.
SPMU removal
Semi permanent make up on brows, lips and eyeliner, which needs the control of a Q-switched pulse rather than a long pulse.
Pigmentation correction
Freckling, sun damage, age spots and other benign pigmented lesions.
Carbon peel facial
The Hollywood facial. Carbon lotion is applied and shattered with the 1064nm pulse for pore, oil and texture work.
Fungal nail eradication
A clinically useful list that runs all year and does not compete with your hair diary.
Four wavelengths and three spot sizes
The CH smart handle fires all four wavelengths as one blended output, and takes three interchangeable tips so the same handpiece covers a back and an upper lip.
755nm
For thin and light hair with a shallow root.
808nm
For hair of average root depth, colour and thickness. The classic diode wavelength.
940nm
For dark hair with a shallow root.
1064nm
For dark hair with a deep root, and the wavelength that lets you treat darker skin safely.
Body tip
15 × 30mm. Legs, backs, chests and arms, where a large footprint turns a full leg into a sensible appointment.
Facial tip
15 × 15mm. Face, underarms, bikini and jawline. Quick enough to be practical, small enough to follow a contour.
Mini tip
Ø8mm. Upper lip, chin, ears, nostrils and around the eyebrow. The round tip reaches where a square one cannot.
- 800W laser output, 2500W total system power
- US Coherent laser bars, Ø6, 100 per cent pure gold tin AuSn stack
- Bar lifespan 20 million shots
- Sapphire contact cooling, C-MAX ice technology rated to minus 20 degrees
- 1 to 90 J/cm², 1 to 10Hz, 10 to 200ms adjustable pulse duration

A Q-switched Nd:YAG, not a long pulse compromise
Tattoo ink is shattered by an extremely short, extremely high peak power pulse. This is a true Q-switched cavity delivering 20 to 30 nanosecond pulses, which is what separates real tattoo removal from a machine that only fades the top layer.
1064nm
Deep pigment and dark inks, black and dark blue in particular, and the wavelength used for the carbon peel facial.
532nm
Superficial pigment and the warmer inks, red, orange and brown, along with freckling and sun spots.
1320nm
Supplied for skin toning and carbon work where a gentler, more diffuse delivery is wanted.
- 500W, up to 1000mJ peak energy
- 20 to 30 nanosecond Q-switched pulse, 1 to 10Hz
- Spot size adjustable from 1 to 10mm
- UK xenon flash lamp, three million shot lifespan
- R20 protocol supported, where the skin tolerates it
Tattoo removal carries a different risk profile from hair removal, and a different training requirement. Where a purchaser already holds a Level 4 Laser and IPL qualification we supply the Level 5 Diploma in Laser Tattoo Removal, RQF, as part of the package rather than repeating Level 4.
It tells you what is wrong before you have to guess
A laser that stops mid list is a bad afternoon. This one monitors itself continuously and names the fault on screen rather than showing a general error and leaving you to ring somebody.
The screen
11.6 or 15.6 inch true colour touchscreen with pre-set clinical protocols, a built in client record database and fifteen languages installed. Your own protocols can be saved and recalled.
The alarms
Water flow, water impurity, temperature and filter change alerts. Handpiece reset detection. Real time voltage and current monitoring on every function of the machine.
- Sapphire crystal, air, closed water circulation, semiconductor and TEC cooling
- Ten to twelve hours of continuous standby working
- Easy change water filter
- Runs on 100 to 110V or 230 to 260V, 50 to 60Hz
Full specification
| Item | Diode laser | Q-switched Nd:YAG |
|---|---|---|
| Wavelength | Quad 755 + 808 + 940 + 1064nm, blended output | 532 · 1064 · 1320nm |
| Power | 800W laser, 2500W machine | 500W |
| Peak energy | 1 to 90 J/cm² | Up to 1000mJ |
| Emitter | US Coherent laser bars Ø6, 100% pure AuSn stack | UK xenon flash lamp |
| Lifespan | 20 million shots | 3 million shots |
| Spot size | Body 15 × 30mm · Facial 15 × 15mm · Mini Ø8mm | 1 to 10mm adjustable |
| Pulse frequency | 1 to 10Hz | 1 to 10Hz |
| Pulse duration | 10 to 200ms | 20 to 30ns |
| Cooling | Sapphire crystal, air, closed water circulation, semiconductor and TEC | |
| Display | 11.6 or 15.6 inch true colour LCD touchscreen | |
| Continuous use | 10 to 12 hours continuous standby working | |
| Electrical | 100 to 110V or 230 to 260V, 50 to 60Hz | |
| Weight | 33kg net, 42kg gross | |
| Shipping dimensions | 63 × 57 × 52cm (W × D × H), volume weight 40kg | |
| Classification | Class 4 laser, BS EN 60825-1 | |
Taken from the manufacturer specification sheet for the ADPL2 CH+ND. If you need the full technical file for your Laser Protection Adviser, ask and we will send it.
Choose the purchase route that suits your clinic
Complete Clinical Package
£11,499 plus VAT. Includes the ADPL-2 CH+ND device, the CH smart handle with all three tips, the Nd:YAG handpiece, engineer installation and calibration, PAT testing, operational handover, LPA package, practical training and the applicable qualification pathway, subject to entry requirements. Complimentary shell colour and logo customisation is included.
Qualified Practitioner Package, 10% off
£10,349.10 plus VAT. Available where the purchaser already holds both a regulated Level 3 Anatomy and Physiology qualification and a regulated Level 4 Laser and IPL qualification. Evidence of both must be supplied and approved before the discount is applied.
Machine Only Purchase, 20% off
£9,199.20 plus VAT. Available for established clinics and suitably qualified practitioners requiring the device only. Excludes engineer installation, PAT testing, LPA services, training and regulated qualifications. Complimentary shell colour and logo customisation remains included.
Training on the full package
- Comprehensive machine operator training at our Southampton city centre academy
- Ofqual regulated Level 4 Certificate in Laser and IPL Skin Rejuvenation, RQF
- Where Level 4 is already held, the Level 5 Diploma in Laser Tattoo Removal, RQF, instead
- Accommodation can be included in the package for those travelling from further afield
- Lifetime access to the online learning portal
Eighteen months, and twelve on the bars
months
The machine, its shell and its electronics.
months
The laser diode bars and the Nd:YAG flash lamp, which are consumable emitting components.
- Professional engineer installation and system set up at your premises
- PAT testing as part of the installation
- Protective eyewear for operator and client included
- Repairs carried out by a UK engineer, with spares and consumables held here
- Brand customisation on the shell and the on screen interface at no extra cost
Our manufacturer trained engineers cover one off repairs and regular servicing agreements. Most faults on this machine are named by the alarm system, and a large proportion are solved on the telephone, which is the difference between an afternoon of lost appointments and a week of them.
Who is responsible for what
| Item | Detail |
|---|---|
| Model | ADPL2, dermatological diode laser system |
| Manufacturer | Beijing Stelle Laser Technology Co., Ltd, Zhongguancun Medical Device Park, Daxing District, 102600 Beijing, China |
| Manufacturer SRN | CN-MF-000038245 |
| Risk classification | Class IIa |
| Basic UDI-DI | 697669578ADPL2V6 |
| Notified body | TÜV Rheinland LGA Products GmbH, number 0197 |
| Certificate | HD 2264988-1, EC Certificate, Full Quality Assurance System, Directive 93/42/EEC Annex II excluding (4). Issued 23 April 2021. Surveillance audit confirmed 25 January 2024. |
| Continued validity | Confirmed by TÜV Rheinland on 12 April 2024 under Article 120 of Regulation (EU) 2017/745 as amended by Regulation (EU) 2023/607. For Great Britain, CE marked devices certified under Directive 93/42/EEC may be placed on the market until the sooner of certificate expiry or 30 June 2028. |
| MHRA registration | Registered 24 May 2024, application reference 2024052201363378, GMDN 58786 |
| UK Responsible Person | MedPath Limited, 27 Old Gloucester Street, London WC1N 3AX |
| Skintastic role | UK importer and distributor |
| Standards applied | IEC/EN 60601-1 · 60601-1-2 · 60601-2-22 · IEC/EN 60825-1 · ISO 13485 |
Registration of a medical device with the MHRA records who is responsible for it. It is not accreditation, certification, approval or endorsement, and we never describe it as such.
Copies of the certificates, the MHRA registration confirmation and the supporting test reports are held on file and supplied with the machine. If your clinic is in a London borough you will also need a special treatment licence from your council before you can treat.
Buying direct from the factory
Clinics are sometimes offered the same machine directly by the manufacturer at a lower headline price. We would rather set out plainly what that price does not include than pretend the offer is not made.
Through Skintastic
Included in the price
- Engineer installation and calibration
- On site PAT testing and operational handover
- Ofqual regulated qualification pathway and Core of Knowledge
- Twelve months of named Laser Protection Adviser support
- Bespoke local rules written for your premises
- Eighteen month UK warranty, twelve months on the diode bars and lamp
- UK engineer servicing, spares and consumables held here
- FCA regulated finance
- Custom shell, engraved logo and LED handpiece branding
Direct from the factory
What lands on you instead
- You become the importer of record, and you are the one the MHRA comes to
- You must hold the technical documentation yourself
- You must produce the certificate for your insurer, your LPA and your council
- In a London borough they ask before granting your special treatment licence
- You must satisfy yourself the exact model is on the notified body certificate
- No UK warranty and no UK engineer
- A fault means shipping a handpiece to Beijing at your cost, and waiting
- No training, no local rules and no LPA
- Those are the documents an inspection actually looks at
A device imported directly from the manufacturer carries none of the first column, and the purchaser themselves takes on the legal obligations of the importer under the UK Medical Devices Regulations.
We are not saying this to protect a margin. We are saying it because we have spent this year sorting out exactly these problems for clinics who bought elsewhere, and it is far harder to fix afterwards than to get right at the start.
Who you will need, and where you will need them
Buying the laser is the straightforward part. What stops clinics trading is usually the paperwork around it, and most people meet these three roles for the first time when a council asks for them. Here is what each one is, in plain terms.
LPA
Laser Protection Adviser
An independent, certified laser safety specialist, normally RPA2000 registered. The LPA carries out a site audit of your treatment room, writes your Local Rules and risk assessment, specifies the correct protective eyewear for your exact wavelengths, and defines the controlled area. This is the appointment a licensing authority will always ask about. Your LPA is not your supplier and should not be.
LPS
Laser Protection Supervisor
Usually you, or a senior member of your team. The LPS is the person on site who is responsible day to day for the Local Rules actually being followed, for keeping the treatment register and the authorised user register, and for making sure nobody operates the machine who is not trained and named. The LPA writes the rules. The LPS lives by them.
EMP
Expert Medical Practitioner
A GMC registered doctor who issues your written Treatment Protocol for that specific device and remains available for clinical advice, on photosensitive medication, on adverse reactions and on contraindications. Their CV, GMC registration and insurance schedule are supplied for your council inspector. Also referred to as an ERHP.
Not every authority writes the EMP into its licence conditions. Some do, some treat it as advisory and some simply ask you to hold a list of practitioners. Our own Laser Protection Adviser recommends appointing one in every case, because a protocol cannot be back-dated and a doctor is only realistically available to you after an incident if they were already retained before it.
Where a licence is required
Licensing is not national. It depends on whether your council holds the local powers, which is why two clinics doing identical work in different towns can face completely different requirements. These are the areas where a licence is commonly required for laser and IPL.
| Area | Authorities |
|---|---|
| All 32 London boroughs | Barking and Dagenham, Barnet, Bexley, Brent, Bromley, Camden, Croydon, Ealing, Enfield, Greenwich, Hackney, Hammersmith and Fulham, Haringey, Harrow, Havering, Hillingdon, Hounslow, Islington, Kensington and Chelsea, Kingston upon Thames, Lambeth, Lewisham, Merton, Newham, Redbridge, Richmond upon Thames, Southwark, Sutton, Tower Hamlets, Waltham Forest, Wandsworth and Westminster |
| Nottinghamshire | Nottingham City, Broxtowe, Gedling and Rushcliffe |
| Kent and Medway | Ashford, Canterbury, Dartford, Dover, Folkestone and Hythe, Gravesham, Maidstone, Medway, Sevenoaks, Swale, Thanet, Tonbridge and Malling, Tunbridge Wells |
| Sussex | Brighton and Hove, Eastbourne, Lewes and Wealden |
| Midlands | Birmingham, Coventry, Derby, Leicester, Northamptonshire, Staffordshire, Stoke-on-Trent and Worcestershire |
| North East | Darlington, Durham, Hartlepool, Middlesbrough and Stockton-on-Tees |
| Wales, Scotland and Northern Ireland | Regulated instead by the national healthcare inspectorates, HIW in Wales, HIS in Scotland and RQIA in Northern Ireland |
This list is a guide and not a substitute for asking. Powers change, and some authorities apply them differently from their neighbours. Before you commit to premises, telephone the licensing team at your own council and ask two questions: do we need a special treatment licence for laser and IPL, and do your conditions require an Expert Medical Practitioner. Get the answer in writing.
If your council does not hold these powers, you are not off the hook. Your obligations under the Health and Safety at Work etc. Act 1974, the Control of Artificial Optical Radiation at Work Regulations 2010 and BS EN 60825 apply everywhere, and your insurer will ask for the same documents whether or not a licence is involved.
Different rules again, and the reason clinics there struggle to buy
Outside England there is no council licence. Instead the clinic itself is registered and inspected by a national healthcare inspectorate, and the standard of documentation they expect is higher, not lower. This is where most machines on the market fall down, and it is the most common reason a clinic in Cardiff or Glasgow cannot find a laser it is allowed to buy.
Wales
HIW
Any independent service using Class 3B or Class 4 laser or IPL equipment must register with Healthcare Inspectorate Wales under the Care Standards Act 2000 and the Independent Health Care (Wales) Regulations 2011, and meet the National Minimum Standards. Inspections are announced, with up to twelve weeks of notice, and findings are published. HIW has issued cautions to providers operating laser services unregistered.
Scotland
HIS
Independent clinics register with Healthcare Improvement Scotland under the regulation of independent healthcare. Registration covers the service and the premises, and the inspection looks at your equipment documentation, your Laser Protection Adviser arrangements and your staff competence together.
Northern Ireland
RQIA
Independent services using lasers and IPL are registered and inspected by the Regulation and Quality Improvement Authority. As in Wales and Scotland, the clinic is registered rather than the premises being licensed by a council.
What an inspector actually asks to see
In all three nations the inspection turns on documents. These are the ones that concern the machine itself, and they are the ones we supply with every machine we supply.
- The notified body certificate, naming the body and its number
- Evidence of device registration and who the UK Responsible Person is
- The manufacturer conformity documentation
- The classification, Class 4 to BS EN 60825-1
- Full instructions for use in English, not a brochure
- Wavelengths, maximum output and pulse parameters for eyewear specification
- Compliance with BS EN 60601-2-22 for the laser
- Test reports and the technical file for your LPA
One distinction worth knowing, because sellers blur it. HIW, HIS and RQIA register the clinic, not the machine. No laser is HIW registered or HIS approved, and anybody telling you otherwise is misleading you. What the machine needs is a complete and accurate documentation pack so that your registration can succeed.
That is the whole difficulty. Plenty of machines are sold in the United Kingdom at attractive prices with a certificate that turns out to cover electrical safety rather than medical device conformity, with a manual that is really a sales brochure, or with no named UK Responsible Person at all. A clinic in Wales or Scotland often only discovers the gap when the inspector asks, by which point they own the machine.
We send the documentation pack before you buy, not after. If you are registering with HIW, HIS or RQIA, ask and we will email the certificates, the registration confirmation, the test reports and the instructions for use, so that you or your adviser can check them against your application before you spend anything.
We supply the paperwork, not just the laser
Every ADPL-2 CH+ND on the Complete Clinical Package is supplied with the governance framework already built around it, so you are not left to assemble it yourself after the machine arrives.
Included with the machine
- Twelve months of named Laser Protection Adviser support
- Site audit report for your treatment room
- Bespoke Local Rules written for your premises
- Risk assessment
- Correct protective eyewear specified for your wavelengths
- Engineer installation, calibration and PAT testing
- Full technical file for your LPA to work from
And the training that goes with it
- Laser Core of Knowledge
- Level 4 Laser and IPL Treatments, RQF, where required
- Level 3 Anatomy and Physiology as the prerequisite
- One to one practical training with live models
- Authorised user records your LPS can actually use
We can also arrange the Expert Medical Practitioner and Treatment Protocol through our Laser Protection Adviser if your council requires one, or if you simply want the clinical cover. Ask and we will quote it separately.
Trained properly, not just shown the buttons
Machine operator training is included on the full package, together with the applicable Ofqual regulated qualification, subject to entry requirements. Level 4 Laser and IPL if you do not already hold it, and the Level 5 Diploma in Laser Tattoo Removal if you do.
- Laser Core of Knowledge
- Level 4 Laser and IPL, RQF
- Level 3 A&P prerequisite
- Lifetime online portal access
Meet the team
When you buy a medical device from us you are buying the people who answer for it afterwards, and on this device that is literally true.

Carla Cooper-Gale
Managing Director
Over fifteen years of specialist laser experience, with more than 7,500 students trained. Carla is the named UK Responsible Person to the MHRA for this device, and she handles the regulatory side of every sale personally.
- Medical device compliance
- Assessor
- IQA
- Level 5 DET

Brenda West
Internal Quality Assurer
A retired senior nurse with decades of clinical experience, Brenda maintains the standards of training, assessment and the award of qualifications. She is the reason our training holds up when an awarding body looks at it.
- Senior nurse, retired
- IQA

Dr Godfrey Town, PhD
Laser Protection Adviser
A Registered Laser Protection Technologist and Medical Physicist with a PhD in laser physics, and decades of experience advising clinical and research environments on laser safety. Every system we supply sits inside his governance framework.
- PhD laser physics
- Registered LPA
- Medical physicist
Skintastic Aesthetic Supplies Ltd is registered in England and Wales, company 11028743, registered office 26 The Avenue, Southampton SO17 1XL. VAT 368 8599 17. Authorised and regulated by the Financial Conduct Authority, firm reference 964293. We act as a credit broker, not a lender. The UK Responsible Person for this Beijing Stelle device is MedPath Limited. Skintastic Aesthetic Supplies Ltd is the UK importer and distributor.
Pay for it out of what it earns
Most clinics finance rather than buy outright, and the ADPL-2 CH+ND is available on business equipment finance over two, three, four or five years. Skintastic Aesthetic Supplies Ltd is FCA authorised, firm reference 964293. We act as a credit broker, not a lender, and we take no commission from the lender.
Work out the payment
Put the price excluding VAT into the calculator and it will show you an indicative monthly figure over each term, with a separate set for businesses trading under three years.
Want a decision today?
Download the Kennet enquiry form, fill it in and send it straight back to us on WhatsApp. We start the background checks the same day and a decision in principle usually comes back within two hours in working hours.
Or just ask
Tell us the machine and the term you have in mind and we will come back with a quotation. No obligation, and no fee for the introduction.
Finance is subject to status and to lender approval. Arranged through Kennet Equipment Leasing Ltd, who work with a panel of lenders. Please send the completed enquiry form back to us on WhatsApp rather than by email. It carries your date of birth, your home address, your property and mortgage details and your consent to a credit search. Email is not encrypted and leaves a copy of the attachment on every mail server it passes through. WhatsApp is encrypted end to end and goes straight to a phone. If you would rather not use WhatsApp, ring us on 02381 946394 and we will arrange another way.
Talk to us before you buy
Two lasers and six treatments is a lot of scope, and the right conversation before you buy saves a difficult one afterwards. WhatsApp is quickest.